ClearCore Library
|
Each ClearCore digital output can drive resistive or inductive loads up to 9 watts (0.375 A). If the load exceeds the output capacity, the connector detects that the output voltage is not at the
proper level and signals an overload condition.
When an overload is detected, the connector's I/O LED Indicators is strobed at 10Hz while the overload condition persists. An error code will be shown on the Under Glow LED Indicator indicating that an overload
occurred on the given connector and persist until the ClearCore is reset.